Category: NRG

Oxygen RTP better than Argon RTP

In continuation of the previous post, its been further observed that O2 RTP treated samples remain unchanged whereas the Ar RTP treated samples started to discolor after a week, as shown in the following images: In order (left to right)1.

Posted in NRG

Track-Etched Membranes

I briefly experimented with the track-etched membranes this morning and found that they are extremely fragile and near impossible to cut. I disassembled a few of the microcons and found that a circular piece of paper the size of a

Posted in NRG

Low Pressure Permeability

I retested the 100K Microcon, 100K Nanosep, and 300K Nanosep membranes at 1000RPM, which in the clinical centrifuge is 4.33psi by my calculations. I retested the 100K Nanosep just to make sure that we had some solid permeability values. I

Posted in NRG

Air tests on wafers with deposited oxide and Burst pressures for w407-413

I tested those membranes from w335 and w341 with approximately 40 nm of deposited oxide on both sides for air permeability and burst pressures. There was tiny amount of air flow (I checked for leak) from few of them which

Posted in NRG

RTP treatment helps!

Posted in NRG

TEM on SiO2 coated membranes

As per Jim’s suggestion, I coated wafers 335 and 341 with 40.6nm SiO2 on top and 42nm SiO2 at backside. The membrane cells have been passed to Anant and Maryna for chemical stability and air flow tests. Today I got

Posted in NRG

wet-wet permeability with 100K and 300K Nanoseps

Just to double check the numbers I calculated on Tuesday I ran some wet-wet trials with 100K and 300K Nanoseps. Based on the wet-dry results we would expect that the permeability for the 100K Nanosep would be higher than that

Posted in NRG

UV Ozone treatment of membranes

UV Ozone treated W404 sample testing (benchtop) : In EGM In L15 In DMEM In each row, the first two samples (from left) are UV Ozone treated whereas the next two are not.It can be observed that there is no

Posted in NRG

Membrane in Sodium Chloride solution

W407 (non treated) in different NaCl salt concentrations (benchtop) : At t=0 In order (from l-r)1. 0.5 M NaCl2. 1.0 M NaCl3. 2.0 M NaCl At t=24 hrs. At t=53 hrs. At t=6 hrs and t=12 hrs the chips were

Posted in NRG

Membrane characteristics (w404 vs. w336)

Membrane stabilityNon treatedW404 samples in DMEM 15um beads on the membrane:15um beads below the slit:In order: (left to right)1. t=02. t=33. t=64. t=105. t=13 hrs.Non treated W336 samples in DMEM15um beads on the membrane:15um beads below the slit:In order: (left

Posted in NRG