Category: NRG

Generating COMSOL Simulations of Actual Pore Geometries

As Greg posted last time, he and I have been working on a manuscript for all of the tomography stuff that we have done that we are going to hopefully submit this week. In that paper, we covered all the…

Posted in NRG

COMSOL model of SiMPore Liftoff device

I drew an approximation of the SiMPore liftoff device and ran the COMSOL model with 1 mL/min urea fluid flow in the upper channels and 2 mL/min dialysate in the bottom channels. With this initial model, the urea was cleared…

Posted in NRG

Instantaneous Clearance per unit area – Animal Study

We’ve calculated our instantaneous clearance numbers for the benchtop studies that use sepcon chips. Even calculating per unit area, our chips are not clearing much volume in these experiments. I believe this is due to the very low flow rate…

Posted in Knowledge, NRG

TEM Tomography for the Identification of Nanopores in Silicon Nanomembranes

Kilean and I are working on submitting a paper to Membranes on some of our electron tomography work. Here’s some of the work that we’ve done so far: Tomography Paper V2_KL

Posted in NRG

Cell Culture on Gradient Microporous-NPN™

Introduction As a continuation to my previous post, I am running a triplicate of cell culture adhesion tests to observe cell lose on our membranes following physiological shear stress. Methods HUVECs (P3,4,5) were seed within our mimetic and left to…

Posted in NRG

Backside Etches of 4682 Release and Widen Pores

We have a wafer that did not clear 500 nm pores (400 nm thick silicon nitride, #4682). There are about 230 chips that could be useful if they were etched a little. I used a SF6 based recipe (15 sccms…

Posted in NRG

Updated Dialysis Research

Microdialysis: Separation of BSA and Cyto C For the past few months I have been studying how well the 75 nm NPN-O membranes are at clearing cyto c while retaining BSA with and without the presence of PEG coating. Additionally,…

Posted in NRG

Impedance Spectroscopy to study neutrophil migration induced permeability

So, I have been working with a 4-probe TEER measurement system to record the changes in endothelial permeability during neutrophil extravasation and other biochemical assays such as thrombin treatment and TNF stimulation. 4-probe systems are sensitive because they don’t suffer from…

Posted in NRG

Preliminary tests on Parylene-C membranes

As the first phase of my thesis, I have been working on parylene C membranes as potential easy-to-make thin polymeric membranes for blood brain barrier models following Dr. Carter’s works. The initial goal is to create membranes with different thicknesses…

Posted in NRG

How a Nanomembrane Prefilter can Enhance Electrophoretic Sensor Capture Under Flow (Part 1)

This will be at least a three part series. Here in Part I, we will establish why adding flow to electrophoretic sensor (ssNP) is a bad idea. In Part II we will show why microfluidics is a benefit to adhesion-based…

Posted in Knowledge, NRG