Category: NRG

Visit from Vincent Tabard-Cossa – May 13

On May 13, Jim McGrath and I are hosting Vincent Tabard-Cossa from the University of Ottawa. We will be interacting with Vincent as a sort of NRG mini-retreat day. See the information below. Vincent’s U Ottawa Page Home Visit Agenda

Posted in NRG

SEM of SiO2 Liftoff samples:

We were targeting a TEOS layer of 300 nm for the SiO2 membrane. The wafers were patterned with ø3 µm pores using S1813 resist (~1.5 µm thick). The target etch time in the Drytek RIE is 4 min 10 s

Posted in NRG

Incorporating a ECM hydrogel into an in vitro microvasculature system – Part II and update

This is just an update for the experiments Tejas and I have been working on for the past two weeks: First, we tried incorporating 20 μl of Geltrex (10 mg/ml, diluted with DMEM from stock concentration: i.e. 15.6 mg/ml) in the

Posted in NRG

Successful SiO2 Membrane Liftoff

Bob and I have been busy for the last couple of weeks going through the fabrication process with the hopes of SiO2 membrane liftoff. The fabrication process was similar to the silicon nitride membrane liftoff. The process is shown in

Posted in NRG

Secrets of the NSF

While serving on an NSF MRI (Major Research Instrumentation program) review panel today the director shared his analysis of funding probabilities as a function of score. The analysis was only done for the Directorate of Math and Physical Sciences, but

Posted in NRG

Incorporating a ECM hydrogel into an in vitro microvasculature system

For the past month, I have been working along with Tejas towards incorporating an ECM-like hydrogel into the back (edged side) of a pnc-Si chip. The purpose of this effort is to add another layer of complexity to Tejas’ in

Posted in NRG

Testing of Printed Transwells for SEPCON chips

Testing was performed on 3D-printed transwell device prototypes for use as culture devices with SEPCON chip integration(Makerbot2 printed Transwells for SEPCON chips). The performed testing attempted to determine the quality of seal of interfaces between all device components. The two

Posted in NRG

Permeance tests with new Omega rotameter

Yaron has acquired an Omega rotameter (FL-3803ST) with interchangeable flow tubes.  The tubes operate in three different ranges low (6-61 mL/min, 042-15-N), medium (150-1,682 mL/min, 082-03-N), and High (1,000-23,752 mL/min, 034-39-N).  I’ve attached an excel file with the calibration data

Posted in NRG, Protocols

Makerbot2 printed Transwells for SEPCON chips

In Nottingham this summer, I attempted to use a Makerbot2 printer to create culture devices for SEPCON chips. I had varying degrees of success, but I was not able to get a good seal between the PLA and gaskets using

Posted in NRG

NP + IgG cleanup in 0.1% Tween 20

Our previous work with reverse centrifugation NPN membranes has shown that they may work for cleaning up excess protein from conjugated NPs.  This initial success used ~20 nm red fluospheres with membranes from wafer 1070 (10-15%, ~45nm) and unlabeled IgG

Posted in NRG