We have successfully plated adipose derived stem cells (ADSC) on microporous silicon nitride (SiN) membranes. Cells plated on nanoporous SiN appeared fine at time of seeding, but membranes were broken at 2 hours – possibly due to media washing or…
We have successfully plated adipose derived stem cells (ADSC) on microporous silicon nitride (SiN) membranes. Cells plated on nanoporous SiN appeared fine at time of seeding, but membranes were broken at 2 hours – possibly due to media washing or…
After a false start with non-microporous TEOS chips, I quickly did an image comparison with truly porous chips using polystyrene beads. The TEOS and Silicon Nitride chips were both fabricated in the single-well CytoVu format (single 2 mm window, 5.4mm…
We have re-started the PEG x-linking project at RIT. One of the goals is to create microwells made of PEG on top of a membrane in order to culture individual cells or small colonies of cells with the potential for…
A group published a paper in Lab on a Chip (2012) using track-etched membranes for electro-osmosis. There are a lot of eerily familiar terms and concepts in the paper. The title even sounds familiar: Low-voltage electroosmotic pumps fabricated from track-etched…
To follow up on some of Dave’s work – I was curious if the ALD alumina affects the strength of pnc-Si membranes. Punchline: 2.5 nm of Alumina seems to increase the burst pressure, while 5.0 nm reduces the burst pressure.…
Dan Mendelson performed gold separations using wafer 255 and has shown that this wafer has a cutoff for gold near 25 nm. Below I have plotted the data of filtrate gold concentration as a function of the feed concentration for…
I continued work with a couple of new wafers and settled on one that lowered the cut-off to between 5 and 10 nm gold particles. For completeness, I will also include some of the old data that has been further…
Motiviation and Background: Nakul and I have been performing a lot of DNA filtration and attempted DNA shearing experiments. We found that large DNA fragments (>1000 and >2000 bp) pass through ~30-40 nm max pore size membranes when pressurized to…
So I think I have confirmed that PDMS is at least one of if not the major contributor to the contact angle problems in the UV-ozone system. Control image before any treatment: I then dried the chip and placed it…
Nakul and I noted last week that the UV-ozone system was not performing. We took pictures of control and treated samples (2x) to measure contact angles on Amorphous, pnc-Si, Oxide and Nitride TEM grids. Our results were pathetic – most…