Vacuole formation on Nitride

Barrett had discovered that growing endothelial cells on pnc-si or tranwells causes vacuoles to form. The vacuoles on pnc-si formed only on the free standing areas of the membrane where there are open pores. The background on pnc-si chips showed

Posted in NRG Tagged with: , ,

Sepcon-transwell discoloration II

I repeated a previous experiment but this time I used samples (no RTP) from W685 in oven @ 37C in DMEM(-FBS). Four type of samples (blank chip with no slits, chip with both intact membranes, chip with one intact membrane

Posted in NRG Tagged with: , ,

Porosity vs Discoloration I

We have known, W683: no visible pores; W684: very few pores; W685: usual porosity. After Vlassak’s view on discoloration, I took samples from above wafers to check if any difference in discoloration can be seen as they have different porosities.

Posted in NRG Tagged with: , ,

Sepcon-transwell discoloration study I

In an earlier post we saw that intact membrane sample discolored slower than the broken one. To establish this, a study using four types of samples from #702 (blank chip with no slits, chip with both intact membranes, chip with

Posted in NRG Tagged with: , ,

Bead Assay in Sepcon

I carried out the bead assay to monitor membrane integrity in Sepcon format. The sample (no RTP) was taken from #703 and put in DMEM(-FBS) @ RT with membrane side facing up. 15um polystyrene beads were allowed to settle on

Posted in NRG Tagged with: , ,

Discoloration CVC vs. AJA Tool

Based on Barrett’s array set up for discoloration, I set up an array experiment to check the discoloration effects between the new and old system ( 2e-7,AJA vs the older 7e-7 CVC ). The wafers from each had a bit

Posted in NRG Tagged with: , , ,

Flipped sample discoloration in Sepcon

We have seen before that in petri dishes, flipped samples (well side up) discolor faster as compared to the ‘membrane side up’ samples. This could be due to local environment trapped below the chip. Hence, I used Sepcon format so

Posted in NRG Tagged with: , ,

Discoloration in flipped sample – II

I repeated the experiment with samples from #703. Two samples were in a dish with one flipped over. Again, the ‘well side up’ sample (flipped) discolored earlier as seen in the 24 hour time point in the figure below.

Posted in NRG Tagged with: , ,

Discoloration in Sepcon

We have seen that discoloration of chips is slower in Sepcons and this has been speculated to be because of the separation between the ‘well side’ and the ‘membrane side’ of the chip existing in the Sepcon format. To further

Posted in NRG Tagged with: , ,

SiO2-deposited discoloration

Last week, Lingyun and I deposited 30nm SiO2 onto both sides of wafers 335, 341 and 345. Unfortunately, these wafers weren’t in too good shape, so there are only a few intact slits without pinholes. I then took a few

Posted in NRG Tagged with: