A bunch of samples from W683 (no RTP) were liquid silanized and used in 3D format to track discoloration in comparison to control sample, in DMEM(-FBS) @ 37C in Oven. I used all the cracked chips which broke while clamping…
A bunch of samples from W683 (no RTP) were liquid silanized and used in 3D format to track discoloration in comparison to control sample, in DMEM(-FBS) @ 37C in Oven. I used all the cracked chips which broke while clamping…
Surface treatments like silanization were seen to slow down discoloration in the past. I carried out liquid amino-silanization (protocol in place) of samples from W683 (no RTP) and used them in both 2D and 3D format to monitor discoloration in…
There were some ideas being thrown around a couple weeks ago about discoloration results. I tested a couple of them out last week. These experiments were with w615 pieces, in the 37C oven in serum-free DMEM. I tested if vacuum…
I did some imaging on the URinc TEM today and took the nice image below from wafer SC021. I wanted to see the correlation between highly diffracting (dark) crystals in our standard lower resolution TEM and the lattice fringes observed…
Recently, I’ve been frustrated with polycarbonate transwells since they are opaque and I couldn’t see cells on them. So, I bought new transwells from BD (Falcon, PET membrane, 0.4um pores) and decided to test these out. I also wanted to…
I carried out a repetition of BSA coating experiment with both 2D and 3D formats. With 2D, I get the same result as before, but surprisingly, in Sepcon 3D format we observe the opposite to what we see in 2D!…
I coated the pncSi samples from W683 (no RTP) with Bovine Serum Albumin (BSA) in Tris-EDTA buffer. Three different concentrations were used: 1 mg/ml, 5 mg/ml and 10 mg/ml (usual range of BSA conc. used for coating Si surfaces). The…
Repeated the previous experiment with W683 and following images were captured after 5 hours of incubation in DMEM(-FBS), Oven @ 37C. I took Sepcon samples with regular thin o-rings, fat o-ring, without o-ring and w/grease in place of o-rings. Also…
I carried out this experiment in order to rule out any effect due to geometry of the setup in our discoloration experiments in Sepcon. I used a cloning ring and mimicked the Sepcon as shown in the figure below. The…
Even though we don’t have defect free membranes, I wanted to tweak the gold setup using membranes with pinholes. Previously I was using the small scale diffusion chamber that I use for protein separations. This setup has a retentate of…