Category: NRG

Take Two: n-Dodecyl β-D-Maltoside Coating on PDMS

Now that I’ve got plenty of fluorescent protein, I’ve moved back to testing protein adsorption to various surfaces. I’ve repeated the n-Dodecyl β-D-Maltoside (“DDM”) coating procedure (reference) with the goal of preventing or heavily decreasing the protein adsorption to the PDMS

Posted in NRG

PEG Structures with Masks from Laser Printer

The overall goal was to see is if it was possible to create a reliable low resolution mask that can be used for crosslinking PEG structures using a laser printer and transparencies sheets. With these masks, I explored to see

Posted in NRG

Single-Well CytoVus w/ SiO2 Membrane – Comparisons

I’ve run a few comparative studies with the CytoVu devices that have SiO2 membranes in them.  From a previous NRG discussion, here is the comparison of a single location with only the fluorescent images, and that same location but with phase included:

Posted in NRG

For real this time: BSA-TRITC conjugation procedure works!

I made this post last week concerning testing this procedure to make sure that the resulting solution is in fact fluorescent BSA and not just a mixture of free BSA and free TRITC. Unfortunately, I exercised my right as a rookie

Posted in NRG

Changes in hydrophilicity of EA treated pncSi after storage in water

In my previous post, I mentioned that the EA treated chips showed decreasing contact angles after their storage in water in contrast to gel-pack or vacuum container. However the EA treatment was 4 days old, and I lacked adequate controls.

Posted in NRG

Procedure for labeling BSA with TRITC works

IMPORTANT: I made a mistake, and mistook what was actually Tetramethylrhodamine-5-Iodoacetamide Dihydroidiode (5-TMRIA) for TRITC. 5-TMRIA is another Rhodamine derivative and has similar chemical properties to TRITC, but does not bind to proteins in the same way. The procedure should

Posted in NRG

Creation and Characterization of Silver Chloride Electrodes

Silver chloride electrodes are useful for microfluidic devices since they can generate current below one volt. This allows them to function without fear of electrolysis confounding experimental results by way of gaseous clogging. Several different methods for coating silver mesh

Posted in NRG

EO at 1 mM vs 100 mM salts & the role of a meniscus in pressure measurements

Presentation from yesterday: PPT, PDF

Posted in NRG

Fluorescence on Single-Well CytoVu – Phalloidin & DAPI

In this trial, bEnd.3 cells were seeded onto three single-well CytoVu devices with SiO2 membranes coated with a 1% Geltrex coating.  After ~27 hours, the cells were fixed and permeabilized (the fixing may be only partial though, as the solution

Posted in NRG

Gold NP separations with SiN-NP

Karl and attempted to pass 10, 20, 40 and 50 nm Au NPs through samples from the center of wafer # 1019 (avg por dia 50-60 nm, porosity ~27%).  The bottles of stock Au from BBI solutions do not have

Posted in NRG